Customers say: The reviews exhibit a positive sentiment, with many customers expressing satisfaction with the services provided. The recurring themes include excellent service, thorough and patient explanations, professionalism, knowledge, promptness, and courteousness. Customers also appreciate the clear explanations, photos, and helpful tips provided by the technicians. Negative reviews are minimal, with most customers expressing gratitude and satisfaction. The weight of the negative reviews is much less than the positive, indicating a positive overall sentiment.
CAME OUT FOR HEATER NOT HEATING PASSED 71” CLIENT NOTCIES WHEN SHE WAKES UP HOUSE IS COLD , WHEN TSTAT IS SET TO 71, 2003 PAYNE PACKAGE UNIT CALLED FOR HEAT SYSTEM KICKED ON AND STARTED HEATING , FURNACE COMPONENTS AND BLOWER KICKED ON , OPENED SYSTEM UP AND EXPOSED ELECTRICAL COMPARTMENT FOUND INDUCER SHELL RUSTED , BLOWER MOTOR LEAKING OIL , AND COIL COMPLETELY BLOCKED TESTING PARTS INDUCER MOTOR CAPACITOR RATED FOR 4uf READING TO 2.5 UNDER ALLOWANCE BLOWER MOTOR CAPACITOR RATED FOR 15 READING TO 13.1 , NOT TO LOW BUT BLOWER MOTOR LEAKING OIL , FLAMES ARENT DANCING AND CHECKING HEAT EXCHANGER THERE IS RUST BUT NO CRACKS , EVAPORATOR COIL IS COVERED WITH DIRT, BLOCKING ANY TYPE OF AIRFLOW ENTERING THE SYSTEM ALSO WOULD RECOMMEND GAS VALVE , GAS VALVE GET STUCK OVER TIME AND AGE , WITH REPLACING PARTS A NEW GAS VALVE WILL EXTEND LIFE RECOMMEND NEW INDUCER MOTOR , BLOWER MOTOR , AND COIL CLEANING
CAME OUT FOR HEATER NOT HEATING PASSED 71” CLIENT NOTCIES WHEN SHE WAKES UP HOUSE IS COLD , WHEN TSTAT IS SET TO 71, 2003 PAYNE PACKAGE UNIT CALLED FOR HEAT SYSTEM KICKED ON AND STARTED HEATING , FURNACE COMPONENTS AND BLOWER KICKED ON , OPENED SYSTEM UP AND EXPOSED ELECTRICAL COMPARTMENT FOUND INDUCER SHELL RUSTED , BLOWER MOTOR LEAKING OIL , AND COIL COMPLETELY BLOCKED TESTING PARTS INDUCER MOTOR CAPACITOR RATED FOR 4uf READING TO 2.5 UNDER ALLOWANCE BLOWER MOTOR CAPACITOR RATED FOR 15 READING TO 13.1 , NOT TO LOW BUT BLOWER MOTOR LEAKING OIL , FLAMES ARENT DANCING AND CHECKING HEAT EXCHANGER THERE IS RUST BUT NO CRACKS , EVAPORATOR COIL IS COVERED WITH DIRT, BLOCKING ANY TYPE OF AIRFLOW ENTERING THE SYSTEM RECOMMEND NEW INDUCER MOTOR , BLOWER MOTOR , AND COIL CLEANING
American standard training , learning and gaining more knowledge in amazing equipment
1 display case refrigerator leaking water - clean drain path 1 display case not cooling- turned on Compressor power switch 1 coca cola refrigerator not cooling- condenser fan motor and Compressor not turning on. Need to change.
CLEAN SPART IGNITOR WITH ABRASIVE CLOTH PAYMENT TYPE: CHECK JOB DATE: 12/10/24 SPECIAL NOTES: 30 DAY LABOR WARRANTY
DUCT CLEANING x8 REPLACE FLAME SENSOR BY JEREMY COMPLIMENTARY FURNACE CLEANING
Found 30 year old package unit - recommended replacing system due to age and poor condition. Cutomer mentioned he has a Home warranty he will contact regarding these recommendations.
Complete
Complete
Estimate in studio city